Our Equipment

1440 PSI/10kPa Recycling Cyclone Separator of Boyd Production Testing Inc.
1440 PSI/10 kPa RECYCLING VERTICAL
CYCLONE TEST SEPARATOR
Maximum Operating Pressure (limited to PSV set pressure) - 1440 psig (9,927.46 kPa)
Maximum Vessel Liquid Storage Capacity - 0.784 bbl (0.124 m3)
Maximum Liquid Rate (operating 1/2 full) - 637.88 bbl/day (101.41 m3/d)
Liquid Retention Time at Maximum Flow Rate - 1 minute
System Maximum Gas Rate (limited by PSV) - 32.32 MMscf/d (915 E3m3/d)
Maximum Gas Flow Rate @ 90% Maximum Pressure - 29.09 MMscf/d (823.812 E3m3/d)
Pressure Relief Maximum Flow Rate - 32.32 MMscf/d (915 E3m3/d)
Flowmeter Maximum Gas Flow Rate @ 90% Maximum Pressure - 38.89 MMscf/d (1,101.24 E3m3/d)
Maximum Vessel Operating Temperature at Maximum Pressure - 100°F (38°C)
Minimum Vessel Operating Temperature at Maximum Pressure - -20°F (-28.8°C)

T145 edit

UNIT DIMENSIONS

Width - 8.9 ft (2.69 m)
Length - 32 ft (9.75 m)
Height - 13.8 ft (4.16 m)
Weight Estimate - 36,400 lbs (16,491 kg)

FLUID TRANSFER SIZE & PRESSURE RATING

Inlet Size - 3 inch (76.2 mm)
Inlet Pressure Rating - 2,000 psig (13,789 kPa)
Gas Outlet - 3 inch (76.2 mm)
Oil Outlet Size - 2 inch (50.8 mm)
Water Outlet Size - 2 inch (50.8 mm)
Outlet's Pressure Ratings - 2,000 psig (13,789 kPa)

FLOW INSTRUMENTATION

EFM Data Aquisition System
Meter Run Senior Daniel's 4 inch (101.6 mm)
Liquid Turbines 1 inch (25.4 mm)

APPROVAL & CERTIFICATIONS

Sour Service NACE Standard MR0175-94
Vessel - ASME Section VIII Div. 1
Piping - ASME B31.3
Alberta Boiler Safety Association